skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Creators/Authors contains: "Setsompop, Kawin"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Abstract PurposeDiffusion encoding gradient waveforms can impartintra‐voxelandinter‐voxeldephasing owing to bulk motion, limiting achievable signal‐to‐noise and complicating multishot acquisitions. In this study, we characterize improvements in phase consistency via gradient moment nulling of diffusion encoding waveforms. MethodsHealthy volunteers received neuro () and cardiac () MRI. Three gradient moment nulling levels were evaluated: compensation for position (), position + velocity (), and position + velocity + acceleration (). Three experiments were completed: (Exp‐1) Fixed Trigger Delay Neuro DWI; (Exp‐2) Mixed Trigger Delay Neuro DWI; and (Exp‐3) Fixed Trigger Delay Cardiac DWI. Significant differences () of the temporal phase SD between repeated acquisitions and the spatial phase gradient across a given image were assessed. Resultsmoment nulling was a reference for all measures. In Exp‐1, temporal phase SD for diffusion encoding was significantly reduced with (35% oft‐tests) and (68% oft‐tests). The spatial phase gradient was reduced in 23% oft‐tests for and 2% of cases for . In Exp‐2, temporal phase SD significantly decreased with gradient moment nulling only for (83% oft‐tests), but spatial phase gradient significantly decreased with only (50% oft‐tests). In Exp‐3, gradient moment nulling significantly reduced temporal phase SD and spatial phase gradients (100% oft‐tests), resulting in less signal attenuation and more accurate ADCs. ConclusionWe characterized gradient moment nulling phase consistency for DWI. UsingM1for neuroimaging andM1 + M2for cardiac imaging minimized temporal phase SDs and spatial phase gradients. 
    more » « less